The commands available for the ActiveFilter context are:
-
EXIT/QUIT– exits CLI and closes connection to Axigen -
HELP– prints this help message -
BACK– cancels any changes made and switches back to the previous context -
DONE– saves the changes and switches back to previous context -
SHOW [ATTR <param>]– shows information about this context -
SET [priority <priority>]– sets the priority of the filter - only usable in an UPDATE operation -
SET [filterName <name>]– sets the name of the filter as defined in the socket/script object sets -
SET [filterType <type>]– sets type of the filter (to which object set belongs) -
SET [applyOn (local and/or relay)]– Specifies where this filter is activated (local, relay delivery or both)